ISV INTEGRATING SPHERE SOURCESFROM VISIBLE TO SWIR CALIBRATION
HGH’s ISV integrating sphere-based sources provide highly accurate and stable reference radiation across the visible, near-infrared (NIR), and shortwave infrared (SWIR) spectral ranges. Compact and easy to operate, these systems are designed to meet the demanding requirements of testing and calibrating advanced optical sensors, including low-light cameras, night vision devices, and SWIR detectors. With real-time luminance and/or radiance monitoring and calibration traceable to international standards, the ISV range guarantees exceptional reliability and performance.
- Home
- Electro-Optical Tests
- Products
- Integrating Sphere Sources
ISV INTEGRATING SPHERE SOURCESFROM VISIBLE TO SWIR CALIBRATION
HGH’s ISV integrating sphere-based sources provide highly accurate and stable reference radiation across the visible, near-infrared (NIR), and shortwave infrared (SWIR) spectral ranges. Compact and easy to operate, these systems are designed to meet the demanding requirements of testing and calibrating advanced optical sensors, including low-light cameras, night vision devices, and SWIR detectors. With real-time luminance and/or radiance monitoring and calibration traceable to international standards, the ISV range guarantees exceptional reliability and performance.
High-performance reference sources for electro-optical system testingMAIN BENEFITS
The ISV Integrating Sphere Sources series from HGH is engineered for laboratories and R&D centers seeking a stable, traceable light source for optical sensor calibration. Each system is built around a high-uniformity integrating sphere, delivering consistent luminance and radiance over time and across a wide spectral range.
ADJUSTABLE LUMINANCE
and radiance outputs with ultra-high stability
UNIFORM OUTPUT PORT
up to 4 inches (≥ 101.6 mm)
WIDE DYNAMIC RANGE
suitable for the most sensiive sensors
REAL-TIME MONITORING
with robust design for both lab and field use
MULTI-INTERFACE CONTROL
including touchscreen, Ethernet, RS232, and IEEE488
RADIOMETRIC AND COLOR TEMPERATURE CALIBRATION
traceable to international primary standars
Whether used for calibrating visible cameras, SWIR focal plane arrays, or radiometers, ISV sources deliver consistent, repeatable results even in challenging low-light testing conditions.
Integrating Sphere Sources designed for ease of use and precision
Intuitive interface and control
The ISV sources are operated through a modern and ergonomic interface. A color touchscreen panel provides direct access to all key settings, allowing users to adjust luminance or radiance values and switch easily between units. Color temperature and night levels are also displayed in real time.
Automated closed-loop control
Thanks to a closed-loop feedback mechanism, the ISV system regulates output levels via an iris attenuator, based on real-time optical readings. This technology ensures outstanding repeatability and ultra-stable radiance or luminance, even during extended testing sessions, while keeping the color temperature and the spectrum constent.
Built-in test equipment (BITE)
All systems come with built-in test tools for internal diagnostics and performance validation, enhancing reliability and user confidence during critical calibration tasks.
Radiometric calibration traceable to International Standards
Every ISV Integrating Sphere source is delivered with a certificate of calibration in luminance or radiance and in color temperature that is traceable to International Primary Standards. This guarantees the accuracy and reliability of your measurements, allowing your lab or production facility to maintain strict quality assurance and meet regulatory requirements.
A dedicated model for SWIR sensor testing – ISV410-SWIRKEY ADVANTAGES
For applications focused on shortwave infrared imaging, the ISV410-SWIR model offers enhanced capabilities:
COOLED INGAAS
detector for stable radiance beyond 1,9 µm
CUSTOM CALIBRATION
over a used-defined SWIR wavelength range
EXCLUSIVE DOUBLE DETECTOR CONFIGURATION
(Silicon + InGaAs) ISV410-DD for extended spectral accuracy
SUPPLIED WITH A PRIMARY STANDRAD TRACEABLE RADIANCE CERTIFICATE
This model is especially suited for testing advanced SWIR cameras used in surveillance, industrial inspection, and scientific research.
Customization and optional accessories
To enhance flexibility and testing versatility, HGH offers a wide range of options for the ISV series:
- Automated shutter for instantaneous ON/OFF radiation control
- Target or filter holders mounted at the output port
- Neutral density filters for dynamic range control
- Resolution targets such as low/high contrast USAF 1951 patterns
- Functional test targets for LSF, MTF, distortion, and FOV measurements
A complete solution for visible to SWIR sensor calibration
Whether you are calibrating a visible-light camera or performing advanced SWIR testing, the ISV integrating sphere sources by HGH provide the precision, consistency, and ease-of-use that modern laboratories demand. The combination of cutting-edge electronics, ergonomic design, and rigorous radiometric certification makes ISV Integrating Sphere sources a trusted choice for system integrators, research centers, and sensor manufacturers worldwide.
Get started with ISV calibration systems
Ready to enhance your electro-optical test capabilities?
- Precise selection of luminance and radiance levels
- Unrivaled temporal stability of radiation
- International Primary Standard traceable calibration