ISV INTEGRATING SPHERE SOURCESFROM VISIBLE TO SWIR CALIBRATION

HGH’s ISV integrating sphere-based sources provide highly accurate and stable reference radiation across the visible, near-infrared (NIR), and shortwave infrared (SWIR) spectral ranges. Compact and easy to operate, these systems are designed to meet the demanding requirements of testing and calibrating advanced optical sensors, including low-light cameras, night vision devices, and SWIR detectors. With real-time luminance and/or radiance monitoring and calibration traceable to international standards, the ISV range guarantees exceptional reliability and performance.

DOWNLOADContact us

ISV INTEGRATING SPHERE SOURCESFROM VISIBLE TO SWIR CALIBRATION

HGH’s ISV integrating sphere-based sources provide highly accurate and stable reference radiation across the visible, near-infrared (NIR), and shortwave infrared (SWIR) spectral ranges. Compact and easy to operate, these systems are designed to meet the demanding requirements of testing and calibrating advanced optical sensors, including low-light cameras, night vision devices, and SWIR detectors. With real-time luminance and/or radiance monitoring and calibration traceable to international standards, the ISV range guarantees exceptional reliability and performance.

DOWNLOADContact us

High-performance reference sources for electro-optical system testingMAIN BENEFITS

The ISV Integrating Sphere Sources series from HGH is engineered for laboratories and R&D centers seeking a stable, traceable light source for optical sensor calibration. Each system is built around a high-uniformity integrating sphere, delivering consistent luminance and radiance over time and across a wide spectral range.

ADJUSTABLE LUMINANCE

and radiance outputs with ultra-high stability

UNIFORM OUTPUT PORT

up to 4 inches (≥ 101.6 mm)

WIDE DYNAMIC RANGE

suitable for the most sensiive sensors

REAL-TIME MONITORING

with robust design for both lab and field use

MULTI-INTERFACE CONTROL

including touchscreen, Ethernet, RS232, and IEEE488

RADIOMETRIC AND COLOR TEMPERATURE CALIBRATION

traceable to international primary standars

Technical data

Integrating Sphere Sources designed for ease of use and precision

Intuitive interface and control

The ISV sources are operated through a modern and ergonomic interface. A color touchscreen panel provides direct access to all key settings, allowing users to adjust luminance or radiance values and switch easily between units. Color temperature and night levels are also displayed in real time.

Automated closed-loop control

Thanks to a closed-loop feedback mechanism, the ISV system regulates output levels via an iris attenuator, based on real-time optical readings. This technology ensures outstanding repeatability and ultra-stable radiance or luminance, even during extended testing sessions, while keeping the color temperature and the spectrum constent.

Built-in test equipment (BITE)

All systems come with built-in test tools for internal diagnostics and performance validation, enhancing reliability and user confidence during critical calibration tasks.

Radiometric calibration traceable to International Standards

Every ISV Integrating Sphere source is delivered with a certificate of calibration in luminance or radiance and in color temperature that is traceable to International Primary Standards. This guarantees the accuracy and reliability of your measurements, allowing your lab or production facility to maintain strict quality assurance and meet regulatory requirements.

A dedicated model for SWIR sensor testing – ISV410-SWIRKEY ADVANTAGES

For applications focused on shortwave infrared imaging, the ISV410-SWIR model offers enhanced capabilities:

Cooled InGaAs
detector for stable
radiance beyond 1.9 µm
Custom calibration
over a user-defined SWIR
wavelength range
Exclusive double
detector configuration
(Silicon + InGaAs) ISV410-DD
for extended spectral accuracy
Supplied with a primary
standard traceable
radiance certificate

COOLED INGAAS

detector for stable radiance beyond 1,9 µm

CUSTOM CALIBRATION

over a used-defined SWIR wavelength range

EXCLUSIVE DOUBLE DETECTOR CONFIGURATION

(Silicon + InGaAs) ISV410-DD for extended spectral accuracy

SUPPLIED WITH A PRIMARY STANDRAD TRACEABLE RADIANCE CERTIFICATE

This model is especially suited for testing advanced SWIR cameras used in surveillance, industrial inspection, and scientific research.

Customization and optional accessories

To enhance flexibility and testing versatility, HGH offers a wide range of options for the ISV series:

  • Automated shutter for instantaneous ON/OFF radiation control
  • Target or filter holders mounted at the output port
  • Neutral density filters for dynamic range control
  • Resolution targets such as low/high contrast USAF 1951 patterns
  • Functional test targets for LSF, MTF, distortion, and FOV measurements

A complete solution for visible to SWIR sensor calibration

Whether you are calibrating a visible-light camera or performing advanced SWIR testing, the ISV integrating sphere sources by HGH provide the precision, consistency, and ease-of-use that modern laboratories demand. The combination of cutting-edge electronics, ergonomic design, and rigorous radiometric certification makes ISV Integrating Sphere sources a trusted choice for system integrators, research centers, and sensor manufacturers worldwide.

Get started with ISV calibration systems

Ready to enhance your electro-optical test capabilities?

  • Precise selection of luminance and radiance levels
  • Unrivaled temporal stability of radiation
  • International Primary Standard traceable calibration

Electro Optical Test Solutions

See all the videos