DCN1000BLACKBODY SOURCES – HIGH-PERFORMANCE INFRARED CALIBRATION
HGH Blackbody sources are low temperature high-performance infrared reference sources designed for superior measurement accuracy. With over 40 years of expertise, HGH offers advanced solutions for laboratories, universities, manufacturers, and maintenance centers worldwide. The DCN1000 blackbody series is ideal for qualifying IR sensors, including high-resolution thermal imagers, high performance thermographic cameras and radiometers.
The DCN1000 series offers exceptional stability and the fastest temperature regulation on the market. It operates in both absolute and differential mode, making it perfect for infrared sensor calibration and thermal imager range calculation.
DCN1000BLACKBODY SOURCES – HIGH-PERFORMANCE INFRARED CALIBRATION
HGH Blackbody sources are low temperature high-performance infrared reference sources designed for superior measurement accuracy. With over 40 years of expertise, HGH offers advanced solutions for laboratories, universities, manufacturers, and maintenance centers worldwide. The DCN1000 blackbody series is ideal for qualifying IR sensors, including high-resolution thermal imagers, high performance thermographic cameras and radiometers.
The DCN1000 series offers exceptional stability and the fastest temperature regulation on the market. It operates in both absolute and differential mode, making it perfect for infrared sensor calibration and thermal imager range calculation.

High-Precision Air-Cooled DCN1000 (Up to 200°C)
The best-seller air-cooled DCN1000 blackbody is a compact and easy-to use reference source for demanding infrared testing applications. It is highly suitable for testing:
High-resolution cameras
Accurate thermographic cameras
Long-range thermal imagers
Key Advantages:
Extended emissive area up to 300 mm x 300 mm
Temperature range: -15°C to +200°C
High thermal uniformity & emissivity
Silent operation & compact emissive head
Exclusive climatic chamber compatibility (operating temperature extended to -55°C to +85°C)

Low-Temperature Fluid-Cooled DCN1000 (-40°C to 150°C)
The fluid-cooled DCN1000 blackbody is designed for applications that require extremely low temperatures with high thermal stability. It achieves outstanding temperature regulation thanks to a refrigerated liquid cooling system circulating through the back of the blackbody head.
Key Advantages:
Extended emissive area up to 300 mm x 300 mm
Temperature range: -40°C to +150°C
Highest thermal uniformity
Fanless & noise-free operation
Compact and efficient design
MAIN BENEFITS
INDUSTRY-LEADING
Stability and precision
WIDE TEMPERATURE RANGE
For various applications
COMPATIBILITY
With infrared testing equipment
USER-FRIENDLY
Operation & Automation features
PROVEN PERFORMANCE
With 40+ years of expertise
Reliable Reference Source for Infrared Sensors
The DCN1000 blackbody sources are engineered to provide accurate and reliable calibration and testing for a wide variety of infrared sensors. Whether you’re working with high-resolution infrared cameras, long-range thermal imagers, or other IR devices, the DCN1000 series ensures the highest levels of performance for testing. The high thermal uniformity and exceptional emissivity of the DCN1000 sources make them an ideal solution for the validation of infrared sensors across multiple industries, from aerospace and automotive to defense and scientific research.
In particular, the air-cooled DCN1000 provides an excellent solution for testing sensors that operate in low temperature ranges, while the fluid-cooled DCN1000 is perfect for applications that require testing in extremely low temperatures. The versatility of the DCN1000 series, combined with its advanced thermal control technology, makes it an indispensable tool for infrared sensor calibration over a wide range of operating conditions.
FEATURES
FEATURES
CONTROL VIA AN INTUITIVE TOUCH-SCREEN PANEL
Built-In Test Equipment (BITE) for diagnostics
REAL-TIME
Temperature display
REMOTE CONTROL
via Ethernet connection
SOFTWARE DEVELOPMENT KIT
(SDK) for integration
SUPPLIED WITH INFRATEST PLATFORM
for automated testing
Perfect for a traceable Testing of High-Resolution Thermal Cameras
High-resolution thermal cameras and long-range thermal imagers are widely used in industries such as security, defense, thermal imager manufacturing and maintenance applications. These cameras rely heavily on accurate temperature readings to deliver precise infrared radiation.
The DCN1000 are delivered with an individual radiometric certificate of calibration over MWIR and LWIR traceable to International Primary Standards, ensuring reliable performances to the thermal imagers tested. Exclusive compensation is applied to the blackbody temperature for a better ease of use (Displayed temperature = Radiated Temperature).
The DCN1000 series plays a critical role in ensuring that these cameras perform at their optimal level. The DCN1000 enables comprehensive testing for non-uniformity correction, bad pixel location, NETD measurement and temperature calibration.
Thanks to its extended emissive area (up to 300 mm x 300 mm), the DCN1000 series ensures uniform thermal radiation across a larger area, providing reliable and accurate calibration for high-performance thermal cameras. Whether you are conducting laboratory-based testing or field calibration on-site, the DCN1000 delivers the stability and precision necessary for professional-grade calibration work.
Get in Touch
Looking for a high-precision infrared calibration solution? Contact us today to learn more about the HGH DCN1000 Blackbody series and how it can enhance your IR sensor calibration processes.














